top of page
GAS SAFETY
Add a Title
STOP TAP
SMOKE ALARM
STATUS
1 Test Street, Irlam, Manchester M44 6NE
14/1/24
BOILER
22/12/23
STOP TAP
22/12/23
SMOKE ALARM
DOWNLOAD

Stop Tap Survey History

STOP TAP

Click for more detail

22/12/23

Last Inspection

22/12/24

Next Safety Check

Under sink

Location of stop tap

Yes

Stop tap in good condition

Pass

Inspection Result

None

Remedial action required

SMOKE ALARM

Click for more detail

22/12/23

Last Inspection

22/12/24

Next Safety Check

Kitchen

Location - Smoke Alarm 1

Bottom of stairs

Location - Smoke Alarm 2

Location - Smoke Alarm 3

Location - Smoke Alarm 4

Location - Smoke Alarm 5

Location - Smoke Alarm 6

Pass

Inspection Result

None

Remedial action required

DOWNLOAD

Smoke Alarm Survey History

GAS CHECKS

Click for more detail

14/1/24

Last Inspection

14/1/25

Next Safety Check

Yes
Meter/emergency control accessible
Yes
Visible equipotential
bonding at meter
Yes
Is gas installation
safe to use
Yes
Gas meter installation pipework satisfactory
Yes
Gas installation tightness test satisfactory
Gas
Supply fuel type
Gas/LPG
Under Stairs

Location

Combi

Boiler type

Baxi

Make

FAFDS57g

Model

Yes

Ventilation satisfactory

RS

Flue type

Yes

Safety controls working

Pass

Flue visual check

Yes

Flue termination satisfactory

Pass

Flue integrity check

Pass

Spillage test satisfactory

Pass

Flue flow satisfactory

0.15

Working pressure/heat input

0.01

Results CO/CO2 ratio

Yes

Flue gas analysis performed

Yes

Appliance safe to use

0

Reason code

No

Warning notice to be issued

Yes

CO alarm working

Pass

Inspection result

Passed

Remedial action required

Kitchen

Location

Bosch

Make

14524G

Model

RS

Flue type

No

Safety controls working

Yes

Ventilation satisfactory

0.15

Working pressure/heat input

Yes

Warning notice to be issued

No

Appliance safe to use

Fail

Inspection result

Hob dials are broken

Remedial action required

Kitchen

Location

Bosch

Make

475454T

Model

RS

Flue type

Yes

Safety controls working

Yes

Ventilation satisfactory

0.15

Working pressure/heat input

No

Warning notice to be issued

Yes

Appliance safe to use

Pass

Inspection result

Passed

Remedial action required

Front Room

Location

British Gas

Make

454AFF

Model

Yes

Ventilation satisfactory

RS

Flue type

Yes

Safety controls working

Pass

Flue visual check

Yes

Flue termination satisfactory

Pass

Flue integrity check

Pass

Spillage test satisfactory

Pass

Flue flow satisfactory

0.15

Working pressure/heat input

Yes

Appliance safe to use

No

Warning notice to be issued

Pass

Inspection result

Passed

Remedial action required

Dan Fleming

Engineer name

Gas Engineer Details
752165

Company Gas Safe Reg No

14/01/24

Date of survey

Email for certificate copy

1254852

Gas Safe Card Serial No

I certify that I have carried out the work on the date of survey. The Customer/ Tenant/ Landlord/ Responsible Person has been informed of any faults/remedial to bring the installation(s) up to standard.

Email for certificate copy

Neil Cousins

Full Name

Resident Details
GAS SAFETY CHECKS
BOILER
HOB
OVEN
FIRE
DOWNLOAD

Boiler Survey History

DOWNLOAD

Gas Safe Certificate